6. Insert the Module adapter into the rear of the shelf directly behind the module slot where the
RFL DS-64NC will be installed.
7. Using Figures 4 through 7 as a guide, connect all power and signal wiring to the Module
Adapter.
8. For steps 9 to 24, refer to Figure 8 for switch locations.
9 On the DS-64NC module, use DIP switches S1-1 through S1-6, to set the module address.
For remote access, each channel module in an IMUX 2000 multiplexer must have a
distinct module address. Valid module addresses are the numbers “1” to “36”,
using the code shown in Table 1. The module address is usually set to the number
of the physical slot in the shelf that the module will occupy. It can be set to any
number from 1 to 36 that is not already being used by another module in the same
multiplexer shelf.
10. Set DIP switch S6-2 for either T1-based or E1-based operation.
If the RFL DS-64NC module is being used in an E1 multiplexer (2MB-based,
2.048-mHz clock), place S6-2 in the ON position. If it is being used in a T1
multiplexer (1.544-mHz bus clock, place S6-2 in the OFF position.
>> text continues on page 14 <<