Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.
RFL VF-10D RFL Electronics Inc.
June 23, 2001 14 (973) 334-3100
11. Select Signaling Delay or No Delay by using DIP switch SW2-1.
Set DIP switch SW2-1 to UP position for no delay, or set
switch to DOWN position for Signaling Delay.
Signaling Delay is the factory default.
12. Select loop start or ground start for Channel 1 by using DIP switch SW1-1.
The factory setting is DOWN for loop start.
13. Select transmit direction by using DIP switch SW10-6.
Place SW10-6 in the UP position to transmit in the B direction and receive from
the A direction. To transmit in the A direction and receive from the B direction,
place SW10-6 in the DOWN position. Unless otherwise specified at time of order,
SW10-6 is set in the DOWN position at the factory to transmit in the A direction,
and receive from the B direction.
14. If you plan to operate the RFL VF-10D module under local control, perform the following
steps; otherwise, go to step 16 for remote control.
a. Set to local control by placing DIP switch SW10-7 in the UP position.
b. Turn service on by placing DIP switch SW10-8 in the UP position.
c. Slide the module into the selected module slot until it is firmly seated and the module
front panel is flush with the top and bottom of the shelf.
d. Go to step 16.
15. If you plan to operate the RFL VF-10D module under remote control, perform the following
steps:
a. Set to local control by placing DIP switch SW10-7 in the UP position.
b. Select normal or enhanced mode using DIP switch SW9-7.
c. Turn service off by placing DIP switch SW10-8 in the DOWN position.
d. Slide the module into the selected module slot until it is firmly seated and the module
front panel is flush with the top and bottom of the shelf.
e. Wait 15 seconds for the RFL VF-10D module’s parameter settings to be loaded into the
shelf Common Module.
f. Pull the module out of the shelf and place DIP switch SW10-7 in the DOWN position.
Do not move SW10-8.
g. Slide the module back into the shelf.