Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL VF-16B RFL Electronics Inc.
January 17, 2007 30 (973) 334-3100
Table 8. continued - Remote configuration settings (“P” codes)
P Code Digit(s) And Switch Equivalent Value
(1)
Description
P05
B 0 0 0 0 0 0 0 0
- - - - - -
00 40 Volts
CH1 RING VOLTAGE
01 45 Volts
10 53 Volts
11 63 Volts
B 0 0 0 0 0 0 0 0
- - - - - - -
0 DC Offset Disabled
CH1 DC OFFSET
1 DC Offset Enabled
B 0 0 0 0 0 0 0 0
- - - - - - -
0 ARD Disabled
CH1 ARD
1 ARD Enabled
B 0 0 0 0 0 0 0 0
- - - - - - -
0 20 mA
CH1 LOOP CURRENT
1 41 mA
B 0 0 0 0 0 0 0 0
- - - - - -
00
None
CH1 RING DELAY
01 200/400ms
10
300/600ms
11
400/800ms
B 0 0 0 0 0 0 0 0
- - - - - - -
For future use