Engine SP Mode Tables - SP2000
SP2-XXX (Drum)
2013 [Env. Correct:PCU] Environment Correction: PCU
2-013-007 CurrentTemp:Displ *ENG Displays the current temperature.
[0 to 100 / 0 / 1 deg/step]
2-013-008 RHumid:FC:Display *ENG Displays the current relative humidity.
[0 to 100 / 0 / 1%RH/step]
2-013-009 AHumid:FC:Display *ENG Displays the absolute humidity.
[0 to 100 / 0 / 0.01 g/m
3
/step]
2-013-010 Env.Range:Bk:Dspl *ENG Displays the previous environmental
condition, which is measured in absolute
humidity.
[1 to 5 / – / 1 /step]
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
2-013-011 Prev.Temp:Bk:Dspl *ENG Displays the previous temperature.
[0 to 100 / 0 / 1 deg/step]
2-013-012 RHumid:Bk:Display *ENG Displays the previous relative humidity.
[0 to 100 / 0 / 1%RH/step]
2-013-013 AHumid:Bk:Display *ENG Displays the previous absolute humidity.
[0 to 100 / 0 / 0.01 g/m
3
/step]
2101 [Color Regist Adj.]
This value is the one of parameters for the automatic line position adjustment and is
adjusted at the factory. However, you must input a value for SP2101-001 after
replacing the laser unit. For details, see "Laser Unit" in the "Replacement and
Adjustment" section. The value should be provided with the new laser unit.
2-101-001 Main Dot: Bk *ENG [–511 to 511 / 0 / 1 dot/step]
Engine SP Mode Tables - SP2000
297