Engine SP Mode Tables - SP3000
SP3-XXX (Process)
3011 [ProCon ManualExe.]
3-011-001 Normal ENG [0 or 1 / 0 / 1 /step]
Executes the normal process control manually
(potential control).
Check the result with SP3-325-001 after
executing this SP.
3-011-002 Density Adj ENG [0 or 1 / 0 / 1 /step ]
Executes the toner density adjustment manually.
Check the result with SP3-325-001 after
executing this SP.
3-011-003 Pre-ACC ENG [0 or 1 / 0 / 1 /step ]
Executes the process control that is normally
done before ACC.
The type of process control is selected with
SP3-041-004.
3-011-004 Full MUSIC ENG [0 or 1 / 0 / 1 /step ]
Executes the process control that is normally
done at the same time as MUSIC. This SP does
the MUSIC (line position adjustment) twice.
3-011-005 Normal MUSIC ENG [0 or 1 / 0 / 1 /step ]
Executes the process control that is normally
done at the same time as MUSIC. This SP does
the MUSIC (line position adjustment) once.
Engine SP Mode Tables - SP3000
397