2-194-007 Execution Result *ENG [0 or 1 / 0 / 1 /step]
0: Completed successfully, 1: Failed
2-194-008 Number of Exe. *ENG [0 to 999999 / 0 / 1 times/step]
2-194-009 Number of Failure *ENG [0 to 999999 / 0 / 1 times/step]
2-194-010 Error Result: C *ENG [0 to 9 / 0 / 1 /step]
0: Not done
1: Completed successfully
2: Cannot detect patterns
3: Fewer lines on the pattern than the target
4: Out of the adjustment range
5 to 9: Not used
2-194-011 Error Result: M *ENG
2-194-012 Error Result: Y *ENG
2220 [Skew Origin Set]
Resets the value of the skew adjustment motor for each color.
These SPs must be executed when a new laser optics housing unit is installed.
2-220-001 C:Skew Motor ENG [Execute]
2-220-002 M:Skew Motor ENG
2-220-003 Y:Skew Motor ENG
2241 [Temp/Humid: Disp]
Displays the environment temperature and humidity.
2-241-001 Temperature ENG [–1280 to 1270 / 0 / 0.1 deg/step]
2-241-002 Relative Humidity ENG [0 to 1000 / 0 / 0.1%RH/step]
2-241-003 Absolute Humidity ENG [0 to 100 / 0 / 0.01 g/m
3
/step]
2302 [Env.Crrct:Trnsfer] DFU
Environmental Correction: Image Transfer Belt Unit
5. System Maintenance Reference
304