3-015-001 Execution: ALL ENG [0 or 1 / 0 / 1 /step]
Executes the manual toner supply to the
development unit.
3-015-002 Execution: COL ENG
3-015-003 Execution: Bk ENG
3-015-004 Execution: C ENG
3-015-005 Execution: M ENG
3-015-006 Execution: Y ENG
3016 [ForcdTonSuply:Set] Forced Toner Supply Setting ([Color])
Specifies the manual toner supply time for each color.
3-016-001 Supply Time: Bk *ENG [0 to 30 / 4 / 1 sec/step]
3-016-002 Supply Time: C *ENG
3-016-003 Supply Time: M *ENG
3-016-004 Supply Time: Y *ENG
3041 [Pro Con Type]
3-041-001 Voltage Control *ENG [0 or 1 / 1 / 1/step ] Alphanumeric
0: FIXED (Use the fixed values for the charge
DC bias and development DC bias set with
SP2-005 and SP2-229.)
1: CONTROL
Enables or disables the process control.
3-041-002 LD Power Control *ENG [0 or 1 / 1 / 1/step] Alphanumeric
0: FIXED (at the value in SP2221-xxx)
1: CONTROL (adjusted by process control)
Selects the LD power control mode.
3-041-003 AtCtrl PrhbtSet *ENG [0 or 1 / 0 / 1/step]
DFU