5504 [Jam Alarm] *CTL -
5-504-001 Sets the alarm to sound for the specified jam level (document misfeeds are not
included).
[0 to 3 / 3 / 1 /step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5505 [Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the error
alarm counter decreases by "1" when an SC is not detected during a set number of
copied sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
5-505-001 - *CTL [0 to 255 / 16 / 100 prints /step]
5507 [Supply/CC Alarm] *CTL -
Enables or disables the notifying a supply call via the @Remote.
5-507-001 Paper Size 0: Off, 1: On
5-507-003 Toner 0: Off, 1: On
5-507-005 Drum 0: Off, 1: On
5-507-006 Waste Toner Bottle 0: Off, 1: On
5-507-007 Transfer Belt 0: Off, 1: On
5-507-008 Fusing Unit 0: Off, 1: On
5-507-080 Toner Call Timing Changes the timing of the "Toner Supply Call" via the
@Remote, when the following conditions occur.
0: At replacement
1: At near end
Engine SP Mode Tables - SP5000