5-987-001 0: OFF / 1: ON *ENG This SP detects that a mechanical counter
device is removed. If it is detected, SC610
occurs.
5990 [SP Print mode]
Prints out the SMC sheets.
5-990-001 All (Data List) CTL -
5-990-002 SP (Mode Data List) CTL
5-990-004 Logging Data CTL
5-990-005 Diagnostic Report CTL
5-990-006 Non-Default CTL
5-990-007 NIB Sumary CTL
5-990-024 SDK/J Summary CTL
5-990-025 SDK/J Appli.Info CTL
5-990-026 Printer SP CTL
5992 [SP Text mode]
Copies the SMC report to a file on an SD card inserted into the SD card slot on the
right side of the machine operation panel.
1: front SD slot
2: back SD slot (service slot)
5-992-001 All (Data List) CTL [Execute]
5-992-002 SP (Mode Data List) CTL [Execute]
5-992-004 Logging Data CTL [Execute]
5-992-005 Diagnostic Report CTL [Execute]
5-992-006 Non-Default CTL [Execute]
5-992-007 NIB Summary CTL [Execute]
5-992-024 SDK/J Summary CTL [Execute]
5. System Maintenance Reference