Maintenance Mode (for Touch Panel Models)
M0C3/M0C4/M0C5/M0C6/M0C7 5-24 SM
Menu Description
Settings Transmission T [100 ms (Default)]
Minimum Pause
In Tone Dial
Sets the minimum pause during tone dialing
[100 ms (Default)/ 150 ms/ 200 ms]
Attenuator of
Pseudo Ring
Sets the attenuator for pseudo ringback tone to the line
[0 to 15 / 10 (Default)/ 1 dB/step]
DTMF Level
Sets the transmission level of DTMF tones.
[-12 dBu / -11 dBu/ -10 dBu (Default)/ -8 dBu/ -6 dBu]
DTMF Delta
Sets the level difference between high band frequency
signals and low band frequency signals when sending DTMF
tones.
[1 dBu/ 2 dBu (Default)/ 3 dBu]
1Dial Tone
Detection
Wait Time
The machine starts dialing after the specified interval without
detection of a dial tone when dial tone detection is set to "No
detection".
[3.5 Sec (Default)/ 7.0 Sec/ 10.5 Sec/ 14.0 Sec]
Timeout Length
This setting sets the time-out length for the 1st dial tone
detection. The machine waits for a dial tone for the specified
time and disconnects itself from the line when no dial tone is
input.
[10 Sec (Default)/ 15 Sec/ 20 Sec/ 30 Sec]
BT (Busy
Tone)
Detection
BT Setting
DFU
[Off/ On(Default)]
BT Frequency
DFU
[300-550 Hz/ 300-650 Hz/ 325-525 Hz/ 340-550 Hz/ 350-500
Hz (Default)/ 350-550 Hz/ 375-475 Hz/ 380-520 Hz]
BT Level
DFU
[-35 dB/ -36 dB/ -37 dB/ -38 dB/ -39 dB (Default)]
BT Cadence
DFU
[0.10/ 0.15/ 0.20/ 0.25/ 0.30/ 0.35/ 0.40/ 0.45/ 0.50 (Default)/
0.75]
Comm RTN Rate
The machine checks the actual data reconstruction errors