Message
I/O module fault
A malfunction with one or more of the modules has occurred.
Check the system.
Radiation too low
The measured radiation level is too low.
Check the radiation sensors.
Check whether the water is too dirty.
Radiation dose too low
The measured radiation dose, which is related to the flow rate, is too low (applicable
if disinfection is based on the radiation dose rather than the calibration curve).
Check the lamps, radiation sensors and flow quantity.
System is locked
The system has been locked due to an invalid activation code.
This means that the system has been operating for more than 30 days without
a valid activation code.
System reinitialized, settings saved
Internal computer malfunction.
Irrigation by the active valve groups has stopped. The preset values have been
erased.
The next start will be performed after the computer has restarted
automatically.
Contact your installer.
System pump malfunction
The system pump or frequency controller is malfunctioning.
Check the pump.
Check the frequency controller.
Check the other pump safeguards.
Check the pump switch.
System pump malfunction (disinfection)
The system pump has generated an error message.
Check the device.
System pump malfunction (cleaning quartz tubes)
The system pump has generated an error message.
Check the device.
System pump malfunction (filter flushing)
The system pump has generated an error message.
Check the device.