<M> Settings / General / System configuration / Protected settings
Type of total flow sensor
Here you select the type of flow sensor used:
l GF15: GF15 sensor with pulse signal (frequency)
l Arad: Arad meter with 4-20mA current signal.
Type of drain flow sensor
Here you select the type of flow sensor used:
l None: No sensor is present.
l GF15: GF15 sensor with pulse signal (frequency)
l Arad: Arad meter with 4-20mA current signal.
EC control
l Yes: Activates EC control for regulating the blending ratio
between drain water and fresh water based on the measured
EC value.
l No: No EC control is present.
Monitor EC
l Yes: Activates a second EC sensor (monitor EC sensor) for
verifying the measurements of the primary EC sensor (control
EC sensor). The control EC sensor provides the measurement
data based on which the controller determines its control
actions.
l No: No monitor EC sensor is present.
pH control
l Yes: Activates pH control for the dosing of acid during the
disinfection process and cleaning of the quartz tubes.
l No: No pH control is present.
Monitor pH
l Yes: Activates a second pH sensor (monitor pH sensor) for
verifying the measurements of the primary pH sensor (control
pH sensor). The control pH sensor provides the measurement
data based on which the controller determines its control
actions.
l No: No monitor pH sensor is present.
Type of radiation sensor
Here you select the type of radiation sensor used for control and
monitoring purposes:
l Analogue: Radiation sensor 0-100%, signal 4-20mA.
l ModBus: Radiation sensor (mW/cm2) via Modbus.