Message
Blending ratio too high
The measured blending ratio is too high.
Check the flow sensor.
Check whether drain water and fresh water are available.
Check the relevant preset value and alarm threshold.
Blending ratio too low
The measured blending ratio is too low.
Check the flow sensor.
Check whether drain water and fresh water are available.
Check the relevant preset value and alarm threshold.
Module unreliable
The module failed to initialize while the controller was starting up.
Switch the controller off and back on.
Please contact Ridder Growing Solutions
An unknown error has occurred.
Unknown alarm
The cause of the generated alarm could not be determined.
Contact your installer.
Disinfected valve is leaking (disinfection)
The system has failed to detect that the disinfected (water) valve has actually closed
during the run time.
Check the disinfected valve.
Disinfected valve is leaking (cleaning quartz tubes)
A leak has been detected in the disinfected (water) valve as the quartz tubes were
being cleaned.
Check the disinfected valve.
Disinfected valve is leaking (filter flushing)
A leak has been detected in disinfected (water) valve as the filter was being
flushed.
Check the disinfected valve.
Quantity of water disinfected too low (cleaning quartz tubes)
The unit has failed to disinfect the required quantity of water due to a dirty quartz
tube.
Cleaning quartz tubes.