Message
Ballast error
An error has occurred with one of the ballasts. Either the ballast is not functioning
correctly or the lamp is faulty.
Check the ballast.
Check the error codes in the UV lamp readouts.
External contact activated (disinfection)
The following error has occurred during disinfection:
The external contact is activated.
Check the external contact provider.
External contact activated (cleaning quartz tubes)
The following error has occurred while the quartz tubes were being cleaned:
The external contact is activated.
Check the external contact provider.
External contact activated (filter flushing)
The following error has occurred while the filter was being flushed:
The external contact is activated.
Check the external contact provider.
External contact activated
The external contact is activated.
Check the external contact provider.
Modbus device alarm
A Modbus device has generated an error message.
Check the device.
Control radiation sensor error
The radiation sensor has generated an error message.
Check the device.
No calibration curve available
Lamp group malfunction
One of the lamps (or ballasts) is malfunctioning. The contacts of the lamps are
arranged in series.
Lamp lifespan exceeded
The lifespan of the lamp has been exceeded.
Replace the lamp preventively to ensure that the radiation intensity remains
sufficiently high.
VitaLite