V L F > H F R E C E I V E R S
f
R & S E K 8 9 5 / R & S E K 8 9 6
User Manual
f
List of Commands
6164.0717.02_01
> A3.50 >
Code Function (entry in) Input
Output
(requested with ?)
Remark
P Inquire PZG line status 0= OFF or
inhibited
1= ON
see A3.7.2
PA Switch preamplifier on or
off
0 or 1 0= OFF
1= ON
see A3.7.21
PB Passband tuning (Hz) see A3.7.1
DEF=0 (see A3.7.25) ±5.00 kHz >5000 to 5000
DEF=1 (see A3.7.25) ±half the cur>
rently effective
bandwidth
<>bandwidth / 2> to
<bandwidth / 2>
PL Inhibit or enable the level
control for PZG line
0 to 2 0= inhibit
1= enable
2= extended
function
see A3.7.3
PS Inhibit or enable the syllabic
control for PZG line
0 to 1 0= inhibit
1= enable
see A3.7.5
Q Quasi>continuous
bandwidth
Parameter a
bandwidth (Hz)
Parameter b
100 to 9000
0 or 1
100 to 9000
0 = fixed
bandwidth
1 = quasi>
continuous
bandwidth
see A3.3.5
R Control type 0 to 7
0= AGC
1= AGC + DGC
2= AGC + DGC
3= AGC
4= AGC + DGC
5= MGC
6= AGC + MGC
7= AGC + MGC
see A3.3.6
REM Disable or enable local
control
0= enable
1= disable
0= enable
1= disable
2= remote con>
trol interface
disabled
see A3.8.11

Table of Contents