EK895.TXT
==============================================================================
EK895 / EK896 Remote Control Software Version 01.02 (c) 1995 ROHDE & SCHWARZ
==============================================================================
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Remote Control Software 01.02 requires
a EK895' SW Version of 01.27 or higher.
a EK896' SW Version of 01.04 or higher.
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Demo software for operating one or several EK895 / EK896' receivers from an
IBM-compatible computer.
Entries made to the program are shown on a simulated front panel to facilitate
operation.
1) Hardware requirements
------------------------
- EK895 program floppy
- IBM-compatible computer with MS-DOS, version 3 or higher
- 512 kB Memory minimum requirements
- RS 232 interface
- program can run on all standard monitors (mono/colour)
- connecting cable for EK895 / EK896 (25-contact Canon / 9-contact Canon)
25-contact Canon EK895 / EK896 9-contact Canon IBM
Pin 7 --------------------------------- Pin 5
Pin 2 --------------------------------- Pin 2
Pin 3 --------------------------------- Pin 3
link Pin 4
Pin 6
link Pin 7
Pin 8
2) Program start
----------------
EK895 [RETURN] (for colour monitor)
EK895 m [RETURN] (for monochrom monitor)
The main menu appears on the screen.
Note: If the message "No connection to receiver EK895 / EK896" appears on the
screen, the following faults may be present:
- EK895 / EK896 switched off
- connecting cable missing or faulty
- baud rate or parity configured incorrectly
(default on EK895 / EK896: 2400, odd) For settings, see also 2.1
- different values set for the device address
All the essential settings and indications can be effected by the simulated
front-panel display on the screen. Parameters are modified by pressing
associated keys which are indicated by highlighted letters on the screen.
Entries are terminated with the RERUTN key. The receiver is then set to the
entered value.
F (frequency): value range 0 to 30000000 Hz, for setting the active receive
frequency
N (bandwidth): setting the active bandwidth with cursor up/down
G (gain control): setting the active control mode with cursor up/down
T (threshold): value range 0 to 120 dB in 1-dB steps
B (BFO): value range -5.000 kHz to 5.000 kHz in 10-Hz steps.