Observing Current Allocations On the Time Plan
R&S
®
SMW-K144
145User Manual 1178.8013.02 ─ 06
"Carrier"
Displayed is the entire carrier bandwidth.
Remote command:
n.a.
First Subframe
Selects the first subframe to be displayed.
Remote command:
n.a.
Subframe
Selects the number of subframes to be displayed.
Change the value to zoom in and out in the time plan. A maximum of 20 subframes
can be displayed, where more than 10 Subframe are allowed if the "Output >
Sequence Length 2".
Remote command:
n.a.