Remote-Control Commands
R&S
®
SMW-K144
203User Manual 1178.8013.02 ─ 06
8.10.4 FRC Commands
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:FRC:STATe.......203
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:FRC:TYPE........203
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:FRC:SCS?........204
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:FRC:ALRB?......204
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:FRC:
MODulation?....................................................................................................... 205
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:FRC:PASize?....205
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:FRC:RBOFfset..205
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:FRC:
STATe <FrcState>
Enables the fixed reference measurement channels (FRC), as defined in TS 38.141.
Parameters:
<FrcState> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Fixed reference channels" on page 152.
Manual operation: See "FRC State" on page 73
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:FRC:
TYPE <FrcType>
Selects the fixed reference measurement channel (FRC).
The currently available FRCs depend on the selected BWP subcarrier spacing SCS)
and selected number of resource blocks.
BWP Configuration Commands