Remote-Control Commands
R&S
®
SMW-K144
188User Manual 1178.8013.02 ─ 06
Return values:
<PointAOffset> integer
Range: 0 to 500
*RST: 0
Example: See Example "Configuring the users and the BWPs"
on page 151.
Usage: Query only
Manual operation: See "RB Offset to Point A" on page 55
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:
DFReq?
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:
DFReq?
Queries the frequency offset between the BWP center and the center frequency of the
carrier.
Return values:
<DeltaFCarrier> float
Range: -40E6 to 40E6
Increment: 1.0
*RST: 0.0
Example: See Example "Configuring the users and the BWPs"
on page 151.
Usage: Query only
Manual operation: See "Δf to Carrier (Centers)" on page 55
8.10 BWP Configuration Commands
● PDSCH Commands.............................................................................................. 188
● ZP and NZP CSI-RS Commands..........................................................................195
● PUCCH Commands..............................................................................................202
● FRC Commands................................................................................................... 203
● PUSCH Commands.............................................................................................. 206
● PUSCH UCI Commands.......................................................................................210
● SRS Commands................................................................................................... 212
8.10.1 PDSCH Commands
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:PDSCh:
DMTB:CTYPe......................................................................................................190
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:PDSCh:
DMTA:CTYPe......................................................................................................190
BWP Configuration Commands