Signal Control and Signal Characteristics
R&S
®
SMW-K144
133User Manual 1178.8013.02 ─ 06
The instrument uses its internal clock reference.
"External Local Clock"
The instrument expects an external clock reference at the local T/M/C connector.
"External Local Clock" requires R&S SMW-B10.
Remote command:
[:SOURce<hw>]:BB:NR5G:CLOCk:SOURce on page 268
Clock Mode
Option: R&S SMW-B10
Sets the type of externally supplied clock.
Remote command:
[:SOURce<hw>]:BB:NR5G:CLOCk:MODE on page 268
Measured External Clock
Provided for permanent monitoring of the enabled and externally supplied clock signal.
Remote command:
CLOCk:INPut:FREQuency?
6.4 Local and Global Connector Settings
Each of the "Trigger In", "Marker" and "Clock" dialogs as well as the "Trigger Marker
Clock" dialog provides a quick access to the related connector settings.
For more information, refer to the description R&S SMW user manual, section "Local
and Global Connector Settings".
6.5 Output Settings
Access:
Select "5G New Radio" > "Output/Power" > "Output".
Output Settings