Parameters:
<DschDataSource> PN9 | PN11 | PN15 | PN16 | PN20 | PN21 | PN23 | PATTern |
DLISt | ZERO | ONE
*RST: PN9
Example: See Example "Configuring the users and the BWPs"
on page 151.
Manual operation: See "(P)DSCH/(P)USCH Data Source" on page 51
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:USCH:DLISt
<UschDataList>
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:DSCH:DLISt <DschDataList>
Selects an existing data list file from the default directory or from the specific directory.
Parameters:
<DschDataList> string
Filename incl. file extension or complete file path
Example: See Example "Configuring the users and the BWPs"
on page 151.
Manual operation: See "(P)DSCH/(P)USCH Data Source" on page 51
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:USCH:PATTern <Pattern>,
<BitCount>
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:DSCH:PATTern <Pattern>,
<BitCount>
Sets a bit pattern as a data source.
Parameters:
<Pattern> numeric
*RST: #H0
<BitCount> integer
Range: 1 to 64
*RST: 1
Example: See Example "Configuring the users and the BWPs"
on page 151.
Manual operation: See "(P)DSCH/(P)USCH Data Source" on page 51
8.9 DL/UL BWP Commands
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:NBWParts.......................... 186
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:NBWParts.......................... 186
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:INDicator.......... 186
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:INDicator.......... 186
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:SCSPacing....... 186
DL/UL BWP Commands