Remote-Control Commands
R&S
®
SMW-K144
266User Manual 1178.8013.02 ─ 06
Usage: Query only
Manual operation: See "Running/Stopped" on page 126
[:SOURce<hw>]:BB:NR5G:TRIGger:SLENgth <TrigSeqLen>
Defines the length of the signal sequence that is output in the SINGle trigger mode.
Parameters:
<TrigSeqLen> integer
Range: 1 to dynamic
*RST: 1
Example: See Example "Configure and enable triggering" on page 162.
Manual operation: See "Trigger Signal Duration" on page 126
[:SOURce<hw>]:BB:NR5G:TRIGger:SLUNit
<TrigSeqLenUnit>
Defines the unit for the entry of the signal sequence length.
Parameters:
<TrigSeqLenUnit> SEQuence | SAMPle
*RST: SEQuence
Example:
SOURce1:BB:NR5G:TRIGger:SEQuence SING
SOURce1:BB:NR5G:TRIGger:SLUNit SEQ
SOURce1:BB:NR5G:TRIGger:SLENgth 2
Manual operation: See "Signal Duration Unit" on page 126
8.18 Marker Commands
[:SOURce<hw>]:BB:NR5G:TRIGger:OUTPut<ch>:MODE..................................................266
[:SOURce<hw>]:BB:NR5G:TRIGger:OUTPut<ch>:DELay..................................................267
[:SOURce<hw>]:BB:NR5G:TRIGger:OUTPut<ch>:PERiod.................................................267
[:SOURce<hw>]:BB:NR5G:TRIGger:OUTPut<ch>:ROFFset...............................................267
[:SOURce<hw>]:BB:NR5G:TRIGger:OUTPut<ch>:FOFFset...............................................267
[:SOURce<hw>]:BB:NR5G:TRIGger:OUTPut<ch>:ONTime................................................267
[:SOURce<hw>]:BB:NR5G:TRIGger:OUTPut<ch>:OFFTime.............................................. 267
[:SOURce<hw>]:BB:NR5G:TRIGger:OUTPut<ch>:MODE <MarkMode>
Defines the signal for the selected marker output.
Parameters:
<MarkMode> SUBFram | FRAM | RESTart | PERiod | RATio | SFNRestart
*RST: FRAM
Example: See Example "Configure and enable standard marker signals"
on page 163.
Marker Commands