5G New Radio Configuration and Settings
R&S
®
SMW-K144
117User Manual 1178.8013.02 ─ 06
●
"PNxx"
An internally generated pseudo-random noise sequence.
●
"Pattern"
An internally generated sequence according to a bit pattern.
Use the "Pattern" box to define the bit pattern.
●
"Data List/Select DList"
A binary data from a data list, internally or externally generated.
Select "Select DList" to access the standard "Select List" dialog.
– Select the "Select Data List > navigate to the list file *.dm_iqd > Select" to
select an existing data list.
– Use the "New" and "Edit" functions to create internally new data list or to edit
an existing one.
– Use the standard "File Manager" function to transfer external data lists to the
instrument.
See also:
●
Section "Modulation Data" in the R&S SMW user manual.
●
Section "File and Data Management" in the R&S SMW user manual.
●
Section "Data List Editor" in the R&S SMW user manual
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:DATA on page 248
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:DLISt on page 248
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:PATTern on page 249
Pattern Length ← Custom ← DCI Content Configuration
If Channel Coding > "On", sets the number of DCI bits, i.e. the number of bits in the
"Pattern" field.
If Channel Coding > "Off", the number of DCI bits is calculated based on the selected
Aggregation Level for the corresponding DCI.
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:BITLength on page 248
5.7 PUCCH Settings
Access:
1. Select "5G New Radio > General > Link Direction > Uplink".
2. Select "5G New Radio > Scheduling".
3. Select "User x BWP x > Content > PUCCH".
4. For the PUCCH allocation, select "User x BWP x > Format = e.g. F0"
PUCCH Settings