Remote-Control Commands
R&S
®
SMW-K144
248User Manual 1178.8013.02 ─ 06
Parameters:
<ChanCodingState> 0 | 1 | OFF | ON
*RST: 1
Example: See Example "Configuring the CORESET settings"
on page 157.
Manual operation: See "Channel Coding" on page 116
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:DATA <DataSource>
Sets the data source for the custom DCI.
Parameters:
<DataSource> PN9 | PN11 | PN15 | PN16 | PN20 | PN21 | PN23 | PATTern |
DLISt | ZERO | ONE
*RST: PN9
Example: See Example "Configuring the CORESET settings"
on page 157.
Manual operation: See "Data Source" on page 116
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:DLISt <DataList>
Selects an existing data list file from the default directory or from the specific directory.
Parameters:
<DataList> string
Filename incl. file extension or complete file path
Example: See Example "Configuring the CORESET settings"
on page 157.
Manual operation: See "Data Source" on page 116
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:BITLength <PatternLength>
If channel coding is enabled ([:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:
SUBF<st0>:USER<dir0>:BWPart<gr0>:ALLoc<user0>:CS:DCI<s2us0>:
STATe 1), sets the number of DCI bits in the custom DCI.
Parameters:
<PatternLength> integer
Range: 12 to 128
*RST: 84
Example: See Example "Configuring the CORESET settings"
on page 157.
CORESET Commands