Remote-Control Commands
R&S
®
SMW-K144
211User Manual 1178.8013.02 ─ 06
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:UCI:
MODE <PuschUciMode>
Defines the information transmitted on the PUSCH.
Parameters:
<PuschUciMode> UCLSch | UCIonly
UCLSch
Control information and data are multiplexed into the PUSCH.
UCIonly
Only uplink control information is transmitted on PUSCH.
*RST: UCLSch
Example: See Example "Configuring the PUSCH settings" on page 159.
Manual operation: See "Mode" on page 79
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:UCI:
ALPHa <PuschUciAlpha>
Sets the scaling parameter alpha.
Parameters:
<PuschUciAlpha> A0_5 | A0_8 | A0_65 | A1_0
*RST: A05
Example: See Example "Configuring the PUSCH settings" on page 159.
Manual operation: See "Scaling Alpha" on page 79
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:UCI:
HARQ:OFF0 <PuschUciHArqOff>
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:UCI:
HARQ:OFF1 <PuschUciHarqOf1>
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:UL:BWP<dir0>:UCI:
HARQ:OFF2 <PuschUciHarq2Of>
Sets the HARQ information offsets OFF0|OFF1|OFF2, each used for the multiplexing
of defined number of HARQ-ACK information bits.
Parameters:
<PuschUciHarq2Of> integer
Range: 0 to 15
*RST: 0
Example: See Example "Configuring the PUSCH settings" on page 159.
Manual operation: See "I_HARQ_Offset,x" on page 79