EasyManua.ls Logo

Ruijie RG-WLAN Series

Ruijie RG-WLAN Series
1243 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration Guide Configuring NTP
Command
ntp update-calendar
Parameter
Description
N/A
Command
Mode
Global configuration mode
Usage Guide
N/A
Configuring a Local Reference Clock Source
Command
ntp master[stratum]
Parameter
Description
stratum: specifies the stratum of a local clock, ranging from 1 to 15. The default value is 8.
Command
Mode
Global configuration mode
Usage Guide
N/A
Disabling NTP
Command
no ntp
Parameter
Description
N/A
Command
Mode
Global configuration mode
Usage Guide
This command can be used to fast disable all functions of NTP and clear all NTP configurations.
Disabling Receiving of NTP Packets on an Interface
Command
ntp disable
Parameter
Description
N/A
Command
Mode
Interface configuration mode
Usage Guide
N/A
Configuration Example
External Clock Reference Mode of NTP
Scenario
Figure 13-5
DEVICE-B is configured to the NTP external clock reference mode.
DEVICE-A is used as the reference clock source of DEVICE-B.
DEVICE-C synchronizes time from DEVICE-B.
Configuration
DEVICE-A configures the local clock as the NTP reference clock source.

Table of Contents