Operating Instructions Cubis
®
MCA 59
System Settings
Parameter Setting Values Explanation
Profile name User input Saves a name assigned for the weighing profile,
e.g.“My Weighing”.
Profile description User input Saves a description for the weighing profile entered (optional).
*Factory setting for the “Standard Weighing” factory-set weighing profile
7.7.5 Parameters in the “Weighing and Print Profiles / YDP30, PC Direct, or SBI Direct” Menu
Parameter Setting Values Explanation
GLP print Off* Deactivates the GLP print.
On The GLP print is always switched on. All printouts contain a GLP
header and a GLP footer.
GLP header or
GLP footer (if GLP
print “On”)
Standard elements Adds elements to or deletes elements from the GLP header:
Dashed line, space line, horizontal line, and signature.
Changes the sequence of the individual elements.
Device information Adds elements to or deletes elements from the GLP header:
Device ID 1, device ID 2, package version, last calibration,
manufacturer, minUSP, model name, and serial number.
Changes the sequence of the individual elements.
Task Adds elements to or deletes elements from the GLP header:
QAPP version, task name, and user name.
Changes the sequence of the individual elements.
Date and time Adds elements to or deletes elements from the GLP header:
Date | time report end, date | time report start, and time zone.
Changes the sequence of the individual elements.
User text Prints an entered description, e.g., the name of the print profile.
Adds or deletes up to four user texts.
Measurement
uncertainty
Adds elements to or deletes elements from the GLP header:
Calibration certificate, accreditation, created by, date, method,
exponent, factor, process accuracy factor, summand.
Changes the sequence of the individual elements.
Weight value print
elements
Standard elements Adds or deletes print elements: Dashed line, date | time of
application, space line, horizontal line, time zone, and
username.
Changes the sequence of the individual elements.
Device information Adds or deletes the print element “Serial number”.
Weighing Adds or deletes the following print elements: Data storage
device ID, weight value block (gross, net, and tare value
“N, T, GC”), and weight value.
Changes the sequence of the individual elements.
Measurement
uncertainty
Adds or deletes the following print elements: Process accuracy,
absolute uncertainty, and relative uncertainty.
Changes the sequence of the individual elements.
* Factory setting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sartorius Cubis MCA2.7S and is the answer not in the manual?

Sartorius Cubis MCA2.7S Specifications

General IconGeneral
BrandSartorius
ModelCubis MCA2.7S
CategoryScales
LanguageEnglish

Related product manuals