Operating Instructions Cubis
®
 MCA  59
    System Settings 
Parameter Setting Values Explanation
Profile name User input Saves a name assigned for the weighing profile, 
e.g.“My Weighing”.
Profile description User input Saves a description for the weighing profile entered (optional).
*Factory setting for the “Standard Weighing” factory-set weighing profile 
7.7.5  Parameters in the “Weighing and Print Profiles / YDP30, PC Direct, or SBI Direct” Menu
Parameter Setting Values Explanation
GLP print Off* Deactivates the GLP print.
On The GLP print is always switched on. All printouts contain a GLP 
header and a GLP footer.
GLP header or 
GLP footer (if GLP 
print “On”)
Standard elements  − Adds elements to or deletes elements from the GLP header: 
Dashed line, space line, horizontal line, and signature.
 − Changes the sequence of the individual elements.
Device information  − Adds elements to or deletes elements from the GLP header: 
Device ID 1, device ID 2, package version, last calibration, 
manufacturer, minUSP, model name, and serial number. 
 − Changes the sequence of the individual elements.
Task  − Adds elements to or deletes elements from the GLP header: 
QAPP version, task name, and user name.
 − Changes the sequence of the individual elements.
Date and time  − Adds elements to or deletes elements from the GLP header: 
Date | time report end, date | time report start, and time zone.
 − Changes the sequence of the individual elements.
User text  − Prints an entered description, e.g., the name of the print profile. 
 − Adds or deletes up to four user texts. 
Measurement 
uncertainty
 − Adds elements to or deletes elements from the GLP header: 
Calibration certificate, accreditation, created by, date, method, 
exponent, factor, process accuracy factor, summand. 
 − Changes the sequence of the individual elements.
Weight value print 
elements
Standard elements  − Adds or deletes print elements: Dashed line, date | time of 
application, space line, horizontal line, time zone, and 
username.
 − Changes the sequence of the individual elements.
Device information  − Adds or deletes the print element “Serial number”.
Weighing  − Adds or deletes the following print elements: Data storage 
device ID, weight value block (gross, net, and tare value 
“N, T, GC”), and weight value.
 − Changes the sequence of the individual elements.
Measurement 
uncertainty
 − Adds or deletes the following print elements: Process accuracy, 
absolute uncertainty, and relative uncertainty.
 − Changes the sequence of the individual elements.
* Factory setting