Section 2: Command Codes
Page 2-48 SATO Programming Reference
Mirror Image
Command Structure <ESC>RM
Example:
<ESC>A103000832<ESC>RM
Placement:
After label data
Default
None
Command Function To allow mirror image printing of data, such as on transparent labels to be
applied to a glass or other transparent surface.
Input to Printer Label #1
<ESC>A
<ESC>A1<ESC>H0100<ESC>V0050<ESC>XL0ABCDEF
<ESC>RM
<ESC>Q1<ESC>Z
Printer Output
Special Notes 1. The <ESC>A1 Media defines the area to be mirrored.
2. This command can be used with the <ESC>% Rotate Fixed Base
Reference Point command. Please note that the reference point rota-
tion is dependent upon the location of the <ESC>% command in the
data stream
3. This command should not be specified more than once in any single
job.
4. This command cannot be used with commands requiring re-editing of
the print area, such as Sequential Numbering, Real time clock or
Copy Image Area.
5. Any data outside the area defined by the <ESC>A1 Media Size com-
mand is not mirrored the command is treated as a command error.
Any print job containing the <ESC>RM command and without any
print data will be treated as a command error.

Table of Contents

Other manuals for SATO E series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SATO E series and is the answer not in the manual?

SATO E series Specifications

General IconGeneral
Print MethodThermal Transfer / Direct Thermal
Max. Print Speed6 ips (inches per second)
Max. Print Width4.09 inches (104 mm)
InterfacesUSB, Ethernet
Media TypeLabels, Tags, Ticket
Ribbon LengthUp to 984 ft (300 m)
Power SupplyAC 100-240V, 50/60 Hz
Print Resolution203 dpi

Related product manuals