Appendix A: Command Code Quick Reference
Page A-14 SATO Programming Reference
CONFIGURATION COMMANDS
Instruction Description Page
AOa Auto Online. Allows the automatic online on power up setting to be
enabled or disabled.
6-14
a = 0 Printer powers up in Online mode
1 Printer powers up in Offline mode.
CLa CR/LF Delete. Deletes the occurance of CR/LF characters in the data
stream.
6-12
a = 0 Do not delete CR/LF.
1 Delete CR/LF
LFa Online Feed. To enable or disable online label feed. 6-14
a = 0 Enables label feed when online.
1 Disables label feed when online.
LHa Zero Slash. Allows printing zeroes with or without a slash. 6-13
a = 0 Prints zeroes without a slash.
1 Prints zeroes with a slash.
I2abcde Serial Interface. Sets the operating parameters for the Serial RS232C
interface. Sets the default printer configuration in Flash ROM. See Serial
Interface Parameters command in the Configuration Commands of
Section 5: Programming Reference of this manual for details.
6-11
IGa Sensor Type. Selects the sensor type. 6-10
a = 0 Reflective (Eye-Mark) sensor.
1 Transmissive (See-Thru) sensor
2 Sensor not used
LD,a,b,c,d,e,
f,g,i, j j
Download Protocol Command Codes. Downloads a user defined set
of Alternate Protocol Command Codes. See Appendix E for details on
the proper usage of this command.
6-2
PCaa,bb
PCF,a,.....z
Printer Setting. Sets the default printer configuration in Flash ROM.
See Printer Setting command in the Configuration Commands of
Section 2: Command Codes of this manual for details.
6-4
PHa Print Type. Selects the thermal printing method. 6-9
a = 0 Thermal transfer printing
1 Direct thermal printing
PMa Print Mode. Selects desired backfeed operation. 6-8
a = 0 No backfeed, continuous operation
1Tear-Off
2 Cut, backfeed after print