Section 6: Configuration Commands
SATO Programming Reference Page 6-13
Zero Slash
COMMAND STRUCTURE <ESC>LHa
a = 0 Print zeroes without slash
1 Print zeroes with slash.
Example: <ESC>LH1
Placement: .In a separate data stream before any label data is
transmitted.
Default: a=0
COMMAND FUNCTION To allow printing of numeric zeroes with a slash.
PRINTER INPUT <ESC>A
<ESC>LH0
<ESC>Z
PRINTER OUTPUT There is no printed output as a result of this command.
Special Notes
1. This command can also be set using the LCD panel. The last setting
received, whether it is via this command or manually input via the LCD
panel will be active.