Section 6: Configuration Commands
Page 6-12 SATO Programming Reference
CR/LF Delete
COMMAND STRUCTURE <ESC>CLa
a = 0 Do not delete CR/LF
1 Delete CR/LF
Example: <ESC>CL0
Placement: In a separate data stream before label data is
transmitted.
Default: a=o
COMMAND FUNCTION To remove CR/LF commands from the dat stream.
PRINTER INPUT <ESC>A
<ESC>CL0
<ESC>Z
PRINTER OUTPUT There is no printed output as a result of this command.
Special Notes
1. This command can also be set using the LCD panel. The last setting
received, whether it is via this command or manually input via the LCD
panel will be active.