Section 2: Command Codes
Page 2-56 SATO Programming Reference
Print Quantity
Command Structure <ESC>Qaaaaaa
aaaaaa = Total number of labels to print (1-999999)
Example: <ESC>Q500
Placement: Just preceding <ESC>Z, unless <ESC>~ exists, then
preceding that. This command must be present in every
print job.
Default: None
Command Function To specify the total number of labels to print for a given print job.
Input to Printer
< ESC>A
<ESC>H0100<ESC>V0100<ESC>WB1M-8485S
<ESC>Q3
<ESC>Z
Printer Output Three labels containing the data “M-8485S” will be printed.
Special Notes 1. 1. To pause during a print job, you must press the LINE key on the
Operator Panel.
2. 2. To cancel a print job, you must turn off the printer, or you may send
the <CAN> code if using the Bi-Com mode. Multi-Buffer jobs can be
cleared with the <ESC>* Clear Print Job(s) and Memory command.
3. 3. When used with the <ESC>F Sequential Numbering command, the
Print Quantity value should be equal to the total number of labels to
be printed.
4. 4. If you do not specify a Print Quantity, the printer will not print a
label.
5. For this command, leading zeroes do not have to be entered. The
command “Q1” is equivalent to “Q000001”.

Table of Contents

Other manuals for SATO E series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SATO E series and is the answer not in the manual?

SATO E series Specifications

General IconGeneral
Print MethodThermal Transfer / Direct Thermal
Max. Print Speed6 ips (inches per second)
Max. Print Width4.09 inches (104 mm)
InterfacesUSB, Ethernet
Media TypeLabels, Tags, Ticket
Ribbon LengthUp to 984 ft (300 m)
Power SupplyAC 100-240V, 50/60 Hz
Print Resolution203 dpi

Related product manuals