Section 2: Command Codes
Page 2-56 SATO Programming Reference 
Print Quantity 
Command Structure  <ESC>Qaaaaaa
aaaaaa =  Total number of labels to print (1-999999) 
Example: <ESC>Q500 
Placement: Just preceding <ESC>Z, unless <ESC>~ exists, then 
preceding that. This command must be present in every 
print job.
Default: None 
Command Function  To specify the total number of labels to print for a given print job. 
Input to Printer 
< ESC>A
<ESC>H0100<ESC>V0100<ESC>WB1M-8485S
<ESC>Q3
<ESC>Z
Printer Output Three labels containing the data “M-8485S” will be printed.
Special Notes  1. 1. To pause during a print job, you must press the LINE key on the 
Operator Panel.
2. 2. To cancel a print job, you must turn off the printer, or you may send 
the <CAN> code if using the Bi-Com mode. Multi-Buffer jobs can be 
cleared with the <ESC>* Clear Print Job(s) and Memory command. 
3. 3. When used with the <ESC>F Sequential Numbering command, the 
Print Quantity value should be equal to the total number of labels to 
be printed.
4. 4. If you do not specify a Print Quantity, the printer will not print a 
label. 
5. For this command, leading zeroes do not have to be entered. The 
command “Q1” is equivalent to “Q000001”.