Section 6: Configuration Commands
SATO Programming Reference Page 6-11
Serial Interface Parameters
COMMAND STRUCTURE <ESC>I2abcde
a= 0
1
2
3
Baud rate, 9600 bps
Baud Rate, 19200 bps
Baud Rate, 38400 bps
Baud Rate, 57600 bps
b= 0
1
8 Data bits
7 Data Bits
c= 0
1
2
No Parity
Odd Parity
Even Parity
d= 0
1
1 Stop Bit
2 Stop Bits
e= 0
1
2
3
4
Single Item Buffer
Multi Item Buffer
X-On/X-Off Flow Control
Bi-Com 4
Bi-Com 3
Example: See above
Placement: Separate data stream sent to printer
Default: Default value set by <ESC>PC command
COMMAND FUNCTION To set the operating parameters of the RS232 Inferface for a job.
INPUT TO PRINTER <ESC>
<ESC>I230011
<ESC>Z
PRINTER OUTPUT
There is no printer output as a result of this command.
SPECIAL NOTES 1. The setting are stored in the EEPROM by this command and
they will remain in effect until a new <ESC>I2 command is
received. Cycling power will have no effect on these settings.
2. To change the value stored in the EEPROM, use the
<ESC>PC Printer Setting command or use the Printer Set-
ting Utility program contained on the CDROM shipped with
the printer.
3. All command parameters must be present in the data stream
sent to the printer.
4. Selecting X-On/X-Off, Bi-Com3 or Bi-Com4 will automatically
place the printer in the Multi Buffer mode.