4 Operation and Configuration
145
S84-ex/S86-ex Operator Manual
RIBBON TENSION ADJUSTMENT
This is to adjust the delay for the timing of the platen roller drive against the
ribbon rewind shaft drive. When ribbon smudge (mark of the friction of the
carbon ribbon and the label surface) is observed, this can be adjusted to
reduce that.
The ribbon is tensed when using a smaller value, and is loosened when
using a larger value.
The setting range varies depending on the following head density:
Note
Shows only for the thermal transfer model.
THROUGHPUT
Set the interval from backfeed to forward feed or from forward feed to
backfeed.
FAST: The interval is shortened and the throughput is improved.
NORMAL: Use the existing interval.
Note
The product may not operate with the FAST setting, depending on the
operating environment.
FEED OFFSET
Set the feed distance in LINERLESS mode.
The setting range is from 000 to 250 mm.
Note
Shows only if PRINTER TYPE in ADVANCED MODE is set to
LINERLESS.
Head Density Setting Range Default
Value
203 dpi 0 - 15 12
305 dpi 0 - 15 5
609 dpi 0 - 15 1