6 Adjusting the Product
277
S84-ex/S86-ex Operator Manual
6.3.4
Adjusting the Paper End Sensor
This adjustment procedure is used when I-mark is selected as the paper end sensor.
When Gap sensor is selected as the paper end sensor, adjust the Gap sensor level as in Section 6.3.3
Adjusting the Gap Sensor Level Manually.
The checking and adjustment procedures for the paper end (I-mark) sensor level are as follows:
1 Go to the SENSOR LEVEL I-MARK(R)
setting screen of SERVICE MODE.
First, check the I-MARK(R) value (voltage) of the paper end (I-mark) sensor when the
liner is placed on the sensor.
2 Open the top cover and unlock the media
feed and media sensor assembly .
3 Physically place the liner without the
label resting over the I-mark sensor.
4 Press the media feed and media sensor
assembly down to lock it.
To get the correct adjustment result, close the
media sensor assembly before performing the
adjustment.
5 Check if the I-MARK(R) value is 2.0 V or
lower.
If not, change ADJUST LEVEL using the /
buttons until the I-MARK(R) value is 2.0 V or lower.
1
2
I-mark sensor
I-MARK(R) level: ≤ +2.0V