6 Adjusting the Product
275
S84-ex/S86-ex Operator Manual
6.3.3
Adjusting the Gap Sensor Level Manually
The adjustment procedure for the Gap sensor level is as follows:
1 Continue the procedure from step 15 of
Section 6.3.2 Adjusting the I-mark
Sensor Level Manually.
If you only want to adjust the Gap sensor level,
after selecting MANUAL in the SENSOR LEVEL
screen, press ENTER button repeatedly until
SENSOR LEVEL GAP(E) screen is shown.
2 On the SENSOR LEVEL GAP(E) screen,
press the / buttons to set ADJUST
LEVEL to 2 and then press the ENTER
button.
The adjustment range of ADJUST LEVEL is from 0
to 3.
We recommend using the initial value, which is 2.
The light reception level adjustment of the Gap
sensor is shown.
First, adjust the “Low” reception level (voltage) of the Gap sensor.
3 Open the top cover and unlock the media
feed and media sensor assembly .
4 Physically place the liner without the
label resting over the Gap sensor.
5 Press the media feed and media sensor
assembly down to lock it.
To get the correct adjustment result, close the
media sensor assembly before performing the
adjustment.
6 Press the / buttons to change ADJUST
LEVEL until the GAP(R) value is 1.0 V or
lower.
The adjustment range of ADJUST LEVEL is from 0
to 127.
Note
The ADJUST LEVEL manipulates the potentiometer that
will be, therefore, reset to 90, the default value when
replacing the PCB or initializing the settings.