6 Adjusting the Product
271
S84-ex/S86-ex Operator Manual
11
The sensor adjustment result shows.
CALIBRATION COMPLETE shows when the
automatic adjustment has succeeded.
CALIBRATION FAILED shows when the automatic
adjustment has failed.
12
Press the ENTER button to proceed to
the next screen.
13
Press the / buttons to select the
following function and then press the
ENTER button.
EXIT CALIBRATION: Exit the automatic sensor
adjustment mode.
Select EXIT CALIBRATION if COMPLETE is
shown in step 11. The product returns to
SERVICE MODE setting screen.
RETRY: Retry the automatic sensor adjustment.
Select RETRY if FAILED is shown in step 11. The
product goes to SENSOR SELECT screen and
repeat steps 6 through 12.
Note
If CALIBRATION FAILED shows in step 11, clean the media sensor and repeat the above steps for auto
adjustment. Select RETRY in step 13. If the problem persists, adjust the media sensor sensitivity level
manually. Refer to the following procedures for manual adjustment.