9 Appendix
395
S84-ex/S86-ex Operator Manual
Cancel signal is enabled when:
waiting for print start signal (PRIN) in online mode.
in offline mode.
an error occurs.
To enable the cancel signal again, turn off the signal and turn back on again.
Note
Cancel is not allowed when receiving print data. Cancel behavior is not guaranteed when receiving data.
You can switch between ON/OFFLINE signals only if Online/Offline can be switched via button
operation.
Input Waveform
Cancel signal
Item
Cancel
100ms
Print Data
(DATA READY)
Print Ready
Online
Offline
Remaining labels to print 
(DATA PRESENT)
Print Ready
Press LINE button
Input Waveform
Online/Offline signal
Item
Online
100ms
Online
Offline
Online/Offline
(ON/OFFLINE)