4 Operation and Configuration
68
S84-ex/S86-ex Operator Manual
CAUTION
Be sure to perform a virus check on the USB memory or SD card before connecting it to the product. SATO
Corporation shall not be held responsible for any product malfunctions caused by a virus spread via USB
memory or SD card.
Note
It is also possible to register, recall and print a SBPL command file that is prepared in advance, as a simple
standalone data, and save it to the SD card or USB memory.
Prepare the data according to the followings:
There should be no command errors in the SBPL command.
The file name should be equal or less than 16 characters, and the extension should be “SSA”. Refer to
below descriptions on the SET NAME screen for usable characters.
The data should be saved to “(SD card/USB memory route)\PR61\DATA” folder.
STANDALONE MODE
Select the following options using the / buttons and then press the
ENTER button.
LOAD: Read and print the file.
SAVE: Save the received print data to a file.
Note
Three beeps will sound if you select SAVE and press
the ENTER
button when there is no received data.
INTERFACE SELECT
Select the memory type using the / buttons and then press the
ENTER button.
Note
When LOAD is selected in the previous screen, three beeps will sound if
the connected memory has no data to load, or the selected memory is
not connected.
When SAVE is selected in the previous screen, three beeps will sound if
the number of registered items is 99, or the selected memory is not
connected.