88
19) Decaf inlet sensor Cap detection at manual inlet:
The machine has a DECAF cap detection
mechanism if magnet (A) is located in the
cap of the manual inlet.
Switch on the "Decaf inlet sensor".
The "16 DECAF cap detection" pa-
rameter is now available under "Gen-
eral Parameters".
On/off
20) Outlet change-over The beverage is dispensed through a "swan
neck".
Switch on "Outlet change-over".
The "12 Outlet change-over" parame-
ter is now available under "Common
settings".
The outlet change-over is only available with
the "mug" beverage.
On/off
Swan neck
21) Telemetry Activates the "Telemetry" configuration
menu.
Switch on "Telemetry".
Machine messages, statistics and
daily counters are transmitted to an
external system.
See "Configuration" -"Date/time/alarm" -
Telemetry.
On/off The standard setting is
"OFF".
22) Eco Mode The boilers automatically switch into tempe-
rature reduction mode after a fixed time follo-
wing dispensing of the last beverage. The
boiler temperatures are reduced to 40°C.
The first temperature reduction takes place
20 min after the last beverage was dispen-
sed or 20 min after the machine was swit-
ched on.
Procedures in "Eco Mode":
If a coffee beverage is selected, the re-
quired boiler water is heated first before
the beverage is dispensed.
If a beverage with hot water is selected,
the boiler water is heated and a warning
signal sounds before the hot water is dis-
pensed.
If a beverage with steam is selected, the
steam boiler is heated. The previous bev-
erage selection is reset. When the steam
temperature is reached, a warning signal
sounds. The beverage needs to be se-
lected again.
On/off The standard setting is
"OFF".
Measurements have
shown that this results in
energy savings of up to
30% .