Operating Instructions Chapter 3
Flexi Classic Gateways
8011834/YT28/2016-03-15 © SICK AG • Industrial Safety Systems • Germany • All rights reserved
17
Subject to change without notice
Flexi Classic gateways
3.2.12 MQD
Module status and output data (output states/module output data)
Bit 7 6 5 4 3 2 1 Bit 0
UE410-MU
UE410-XU
BYP MUTE StRq B StRq A Q4 Q3 Q2 Q1
UE410-GU O
P
O
N
StRq
local
StRq
global
Q2 Q2 Q1 Q1
UE410-8DI - - Q
B
Q
A
UE410-MM
UE410-XM
OVR MUTE OVReq StRq Q4 Q3 Q2 Q1
UE410-MDI S4 OVR CS C1
With the UE410-MU/XU, the functions StRq A and MUTE are output on Q3 in program 3.
For this reason you would be better using the status bits 4 and 7 for the output of these
states.
Q1-Q4 Output states UE410-MU/
UE410F GU/UE410-XU/UE410-MM/
UE410-XM
0 = Output is inactive
1 = Output is active
Module output data UE410-8DI
0 = Output is inactive
1 = Output is active
Q
A
, Q
B
Q
A
/ Q
B
are set if:
all inputs on the function group (A or B) are in the valid ON state
the OR function is valid
the bypass function is valid
Module output data UE410-MDI 0 = Output is inactive
1 = Output is active
S4, OVR, CS, C1
Module output data are the same as module input data.
See module input data (input states)
OVR Req
(only UE410@MM/XM)
Override request, waiting for
override
0 = Not currently waiting
1 = The System is in the Override
required state and is expecting the
actuation of the restart button
StRq A,
StRq B
Reset request, waiting for reset
input group A/B
0 = Not currently waiting
1 = Waiting for a reset signal; is
deleted, once the reset has been
made
StRq Reset request, waiting for reset 0 = Not currently waiting
1 = Waiting for a reset signal; is
deleted, once the reset has been
made
StRq local,
StRq global
(only UE410-GU)
Reset request, waiting for local
reset, waiting for global reset
0 = Not currently waiting
1 = Waiting for a reset signal; is
deleted, once the reset has been
made
Tab.
13
:
MQD

Table of Contents