116 FLOWSIC500 · Operating Instructions · 8025733/1GMJ/V4-2/2022-07 · © SICK Engineering GmbH
Maintenance and meter exchange
Subject to change without notice
7.4.6 Backup of user-specific configuration of installed gas flow meter
1 Connect to device, p. 71, §4.3.1.
2 Open the “Meter Replacement” tile in the “Service” menu.
3 Click “Backup Parameter” to backup the parameters of the currently installed gas flow
meter.
Fig. 52 Parameter backup
4 Save the parameter file:
Click “Save as” to choose a storage location for the parameter file.
Click “E-mail” to send the file per e-mail. The file is appended to an e-mail when an
e-mail client is available.
Fig. 53 Save the parameter file
5 Click “Close” after storing the csv file.
NOTICE:
The parameter set is required after exchanging the gas flow meter to transfer
the customer-specific or device-specific parameters to the new gas flow meter.