EasyManua.ls Logo

SICK FLOWSIC500

SICK FLOWSIC500
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
116 FLOWSIC500 · Operating Instructions · 8025733/1GMJ/V4-2/2022-07 · © SICK Engineering GmbH
Maintenance and meter exchange
Subject to change without notice
7.4.6 Backup of user-specific configuration of installed gas flow meter
1 Connect to device, p. 71, §4.3.1.
2 Open the “Meter Replacement” tile in the “Service” menu.
3 Click “Backup Parameter” to backup the parameters of the currently installed gas flow
meter.
Fig. 52 Parameter backup
4 Save the parameter file:
Click “Save as” to choose a storage location for the parameter file.
Click “E-mail” to send the file per e-mail. The file is appended to an e-mail when an
e-mail client is available.
Fig. 53 Save the parameter file
5 Click “Close” after storing the csv file.
NOTICE:
The parameter set is required after exchanging the gas flow meter to transfer
the customer-specific or device-specific parameters to the new gas flow meter.

Table of Contents

Related product manuals