2.6 Data processing in
2.6.1 Logbooks
The FLOWSIC500 stores events and parameter changes in the following logbooks:
● Event logbook
All events with timestamp, user logged on and totalizer level, max. number of entries:
1000
When the Event logbook is 90% full, the FLOWSIC500 changes to device status
“Warning”, warning W-2001 is shown on the display.
When the Event logbook is full, the FLOWSIC500 changes to device status
“Malfunction”, error E-3001 is shown on the display (→ p. 102, §6.2, “Status messages”).
● Parameter logbook
All parameter changes with timestamp, user logged on, totalizer level, old and new
parameter value and register number, maximum number of entries: 250
The oldest entries are overwritten when the Parameter logbook is full.
● Metrology logbook
All changes to selected custody-relevant parameters (→ p. 31, §2.8.2), with parameter
locking switch activated with timestamp, user logged on, totalizer level, old and new
parameter value and register number, maximum number of entries: 100
When the Metrology logbook is full, custody relevant parameters can be modified only
after the parameter locking switch has been opened. The FLOWSIC500 changes to
device status “Warning”, warning W-2002 is shown on the display (→ p. 102, §6.2, “Sta-
tus messages”).
● Gas composition logbook
All parameter changes of the gas composition for the volume conversion with
timestamp, user logged on, totalizer level, old and new parameter values and register
number, maximum number of entries: 150
The oldest entries are overwritten when the Gas composition logbook is full.
The data are stored in non-volatile memory. All logbooks can be viewed, stored and reset
with the FLOWgate
TM
operating software. The Event logbook can be viewed after logon as
“User” or “Authorized user” on the device.
The following parameters are displayed:
● Event type
● Number of events
● Short description
● Timestamp
NOTICE:
If the optional feature "Load recording device with maximum load display" fea-
ture is activated and the event logbook is full, the device time can be corrected
even if the operation is not logged. That the time has been set is evident from
the status of the measuring period entry. Updating is the responsibility of the
plant operator.