128 FLOWSIC500 · Operating Instructions · 8025733/1GMJ/V4-2/2022-07 · © SICK Engineering GmbH
Maintenance and meter exchange
Subject to change without notice
8 In the dialog that opens, select whether the totalizer levels are to be used from the
saved parameter set or should be reset. The operating company is responsible for
deciding whether to accept or reset the volume counters.
Fig. 57 Counter values
9 Confirm with “OK”.
10 The serial numbers of the pressure and temperature sensor are queried for gas flow
meters with external pressure and temperature technology.
Fig. 58 Serial numbers for pressure and temperature sensors
11 Check the serial numbers.
12 Enter the new serial numbers when the numbers do not match the serial numbers of
the installed pressure and temperature sensors.
13 Confirm with “OK”.
14 Check the serial number of the adapter; enter the serial number when different from
the one stored.
Fig. 59 Adapter serial number
15 During transfer of the parameter values, the sequence is shown in a progress bar.
16 Confirm the upload with “OK” after completion of the upload.
The “Meter exchange report” is created.