32 FLOWSIC500 · Operating Instructions · 8025733/1GMJ/V4-2/2022-07 · © SICK Engineering GmbH
Product description
Subject to change without notice
Table 6 Custody relevant parameters - gas flow meter with volume conversion
Parameter Description
Max. reverse flow volume Buffer volume for reverse flow
Symbols for measured value displays Symbols used on the display (formula symbols)
Calculation interval Cycle time for updating measured values (pressure, temperature)
and calculation of the compressibility factor
Calculation method Calculation method for the compressibility factor
Value range check Checking the input parameters for the conversion algorithms
Reference conditions Reference conditions for density and heating value
Heating value unit Heating value unit
Density value selection Selection of relative density or standard density
Basic pressure Pressure standard conditions
Basic temperature Temperature standard conditions
K-factor (fixed) Figure for method "Fixed value" when the calculation of the
K-factor is incorrect
Default value for Molar mass Default value, when the calculation of the molar mass is
disturbed
p Lower alarm limit Lower warning limit for the pressure which can be set by the
customer
p Upper alarm limit Upper warning limit for the pressure which can be set by the
customer
p Default value Fixed value of measurement pressure
p Unit Unit for pressure values
Atmospheric pressure Ambient pressure
p Serial number Serial number of pressure sensor
p Offset Offset for pressure sensor adjustment
p Adjust factor Factor for pressure sensor adjustment
T Lower alarm limit Lower warning limit for the temperature which can be set by the
customer
T Upper alarm limit Upper warning limit for the temperature which can be set by the
customer
T Default value Fixed value of measurement temperature
T Unit Unit for temperature values, used for entry and display
T Serial number Serial number of temperature sensor
T Offset Offset for temperature sensor adjustment
T Adjust factor Factor for temperature sensor adjustment
Measuring period Period for billing archive
Gas hour Billing hour for the day archive
Gas day Billing day for month archive