Programming an Extension
47
Step by Step
Collect Call Barring for a UCD Subscriber
Group
When Collect Call Barring is activated, all collect calls to
a UCD Group are automatically rejected by the system.
The system bypasses Collect Call Barring for members
and non-members of the UCD Group. This means that
Collect Call Barring is only acknowledged.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
Enter the UCD Group number (e.g., 790).
or Activate/Deactivate Collect Call Barring:
= To activate
= To deactivate (default)
Enter the next UCD Group number
or
Press this key.
Initial state for Programming Mode.
Call Waiting Message for UCD Queues
This feature enables assigning a message or Music On
Hold for a UCD Group extension when all extensions in
the group are busy.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
Enter the UCD Group number (e.g., 790).
0 70
*
#
*
#
#
If a call has been answered at least once by the
system, Collect Call Barring cancels the blocking.
When an incoming call over a digital line is for-
warded for not being answered (*14), and Col-
lect Call Barring is activated, the call will ring at
the First Attendant for the external line.
0 2 4