Technical specifications
11.8 Technical specifications
Mobile Panels 2nd Generation
Operating Instructions, 09/2018, A5E33876626-AC
241
Safety characteristics (compatibility of Mobile Panels 2nd Generation with PN basic and
PN plus connection boxes)
In accordance with IEC 61508
Maximal attainable safety integrity level
SIL2 (Proof Test Interval 1 year)
Mode of operation
High and low demand mode
Hardware fault tolerance (HFT) 1
Classification
B
Repair Time 100 h
Probability of a dangerous failure per hour (PFHd)
< 3 × 10
-8
1/h
Probability of a dangerous failure on demand (PFDavg)
< 2 × 10
-4
Mission Time
20 years
In accordance with ISO 13849-1
Meantime to Failure (MTTFd)
High
Diagnostic Coverage (DCavg)
Medium
Performance Level
d
Category
3
Safety characteristics (compatibility of Mobile Panels 1st Generation with
connection box compact, connection box standard and connection box advanced)
In accordance with IEC 61508
Maximal attainable safety integrity level
SIL2 (Proof Test Interval 1 year)
Mode of operation
High and low demand mode
Hardware fault tolerance (HFT)
1
Classification
B
Repair Time
100 h
Probability of a dangerous failure per hour (PFHd)
≤ 1,25 × 10
-7
1/h
Probability of a dangerous failure on demand (PFDavg)
< 6 × 10
-4
Mission Time
20 years
In accordance with ISO 13849-1
Meantime to Failure (MTTFd)
High
Diagnostic Coverage (DCavg)
Medium
Performance Level d
Category
3
The safety characteristics according to IEC 61508 and ISO 13849-1 in the table above are
based on the SN 29500 and an ambient temperature of 60 °C.