EasyManuals Logo
Home>Siemens>Control Panel>SIMATIC HMI series

Siemens SIMATIC HMI series User Manual

Siemens SIMATIC HMI series
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
Overview
1.8 Terms for fail-safe operation
Mobile Panels 2nd Generation
26 Operating Instructions, 09/2018, A5E33876626-AC
Safety-related operator controls
A fail-safe Mobile Panel comes equipped with the two safety-related operator controls
"Emergency stop / stop button" and "Acknowledgment button". All other operator controls are
not safety-related operator controls.
Fail-safe operation
In a hardwired or PROFIsafe-based F-system, you operate the plant or a plant section in fail-
safe mode. In fail-safe mode, the safety-related operator controls emergency stop/stop
button and enabling buttons are active.
For a hardwired F-system: Fail-safe mode runs via a fixed connection with a safety relay.
In a PROFIsafe-based F-system: The HMI device in fail-safe mode detects the signals of
the "emergency stop / stop button" and "enabling button" safety-related operator controls;
communication with the F-system is performed via PROFIsafe.
When configuring the safety functions with the STEP 7 Safety Advanced optional
package, fail-safe operation according to SIL 3 or Performance Level e and Category 4 is
possible with an HMI device of the type KTPx00F Mobile.
The safety-related operator controls can be configured as fail-safe inputs in the safety
program.
Emergency stop, stop
The operator presses the emergency stop / stop button to activate either an emergency stop
or a stop.
The emergency stop is an emergency action that is intended to stop a process or
movement entailing danger. All machines that are assigned to the trigger are immediately
brought to a safe state via the emergency stop.
The emergency stop / stop button of the HMI device brings about a safety-related stop of
the plant or machine in accordance with EN 60204-1, Section 9.2.5.3.
Whether the emergency stop / stop button causes an "emergency stop" or "stop" function
must be decided upon and configured on the basis of the risk assessment.

Table of Contents

Other manuals for Siemens SIMATIC HMI series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC HMI series and is the answer not in the manual?

Siemens SIMATIC HMI series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC HMI series
CategoryControl Panel
LanguageEnglish

Related product manuals