Motor data
23 Phase number and type of current for the motor
24 Temperature class Th.Cl.
25 Symbols (IEC 60617-2): = brake
26 Rated braking torque T
Br
[Nm]
27 Brake supply voltage U [V]
Frequency 1
28 Rated frequency f [Hz]
29 Rated voltage / range U [V]
30 Circuit, graphical symbols according to DIN EN 60617 Part 6 / IEC 60617-6
31 Rated current I
N
[A]
32 Power factor cos φ
33 Rated power P
N
[kW], duty type (if ≠ S1)
34 E󹪟ciency class marking according to IEC 60034-30
35 Rated speed n
N
[rpm]
Frequency 2
36 Rated frequency f [Hz]
37 Rated voltage / range U [V]
38 Rated current I
N
[A]
39 Power factor cos φ
40 Circuit, graphical symbols according to DIN EN 60617 Part 6 / IEC 60617-6
41 Rated power P N [kW], duty type (if ≠ S1)
42 E󹪟ciency class marking
43 Rated speed n
N
[rpm]
44 Motor designation, active part
If you use the Startdrive commissioning tool and a SIEMENS motor, you only need to specify
the article number of the motor, otherwise you must note the data from the motor rating
label.
Pay attention to the connection of the motor (star connection [Y] or delta connection [Δ] ).
Note the appropriate motor data for connecting.
Motor ambient temperature if it di󹪜ers from the factory setting = 20° C.
5.3.2 Converter factory setting
Motor
With its factory settings, the converter is set up for an induction motor suitable for the power
rating of the Power Module.
Commissioning
5.3 Prepare commissioning
Distributed converter for SIMOGEAR geared motors