EasyManua.ls Logo

Siemens SINAMICS G110M - Examples

Siemens SINAMICS G110M
428 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.6.7 Examples
Read request: Read out serial number of the Power Module (p7841[2])
To obtain the value of the indexed parameter p7841, you must 󹪝ll the telegram of the parameter
channel with the following data:
PKE, Bit 12 … 15 (AK): = 6 (request parameter value (󹪝eld))
PKE, Bit 0 … 10 (PNU): = 1841 (parameter number without o󹪜set)
Parameter number = PNU + o󹪜set (page index)
(7841 = 1841 + 6000)
IND, bit 8 … 15 (subindex): = 2 (index of parameter)
IND, bit 0 … 7 (page index): = 90 hex (o󹪜set 6000 corresponds to 90 hex)
Because you want to read the parameter value, words 3 and 4 in the parameter channel for
requesting the parameter value are irrelevant. They should be assigned a value of 0, for
example.
3DUDPHWHUFKDQQHO
3:(KLJKUGZRUG3:(ORZWKZRUG,1'QGZRUG
3DJHLQGH[3DUDPHWHUQXPEHU6XELQGH[3DUDPHWHUYDOXH
3.(VWZRUG
'ULYHREMHFW,QGH[$.


Figure 8-16 Telegram for a read request from p7841[2]
Write request: Change restart mode (p1210)
The restart mode is inhibited in the factory setting (p1210 = 0). In order to activate the automatic
restart with "acknowledge all faults and restart for an ON command", p1210 must be set to 26:
PKE, bit 12 … 15 (AK): = 7 (change parameter value (󹪝eld, word))
PKE, bit 0 … 10 (PNU): = 4BA hex (1210 = 4BA hex, no o󹪜set, as 1210 < 1999)
IND, bit 8 … 15 (subindex): = 0 hex (parameter is not indexed)
IND, bit 0 … 7 (page index): = 0 hex (o󹪜set 0 corresponds to 0 hex)
PWE1, bit 0 … 15: = 0 hex
PWE2, Bit 0 … 15: = 1A hex (26 = 1A hex)
3DUDPHWHUFKDQQHO
3:(KLJKUGZRUG3:(ORZWKZRUG,1'QGZRUG
3DJHLQGH[3DUDPHWHUQXPEHU6XELQGH[3DUDPHWHUYDOXHELW3DUDPHWHUYDOXHELW
3.(VWZRUG
$.


Figure 8-17 Telegram, to activate the automatic restart with p1210 = 26
Write request: Assign digital input 2 with the function ON/OFF1 (p0840[1] = 722.2)
In order to link digital input 2 with ON/OFF1, you must assign parameter p0840[1] (source, ON/
OFF1) the value 722.2 (DI 2). To do this, you must populate the telegram of the parameter
channel as follows:
PKE, bit 12 … 15 (AK): = 7 hex (change parameter value (󹪝eld, word))
PKE, bit 0 … 10 (PNU): = 348 hex (840 = 348 hex, no o󹪜set, as 840 < 1999)
Advanced commissioning
8.6 Drive control via PROFIBUS or PROFINET
Distributed converter for SIMOGEAR geared motors
202 Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL

Table of Contents